دانلود مقاله انگلیسی رایگان:تضمین کاهش تقاضای بار اوج بر اساس تغییر استراتژی DSM برای کاربردهای شبکه هوشمند - 2020
دانلود بهترین مقالات isi همراه با ترجمه فارسی
دانلود مقاله انگلیسی مدیریت انرژی رایگان
  • Ensuring the reduction in peak load demands based on load shifting DSM strategy for smart grid applications Ensuring the reduction in peak load demands based on load shifting DSM strategy for smart grid applications
    Ensuring the reduction in peak load demands based on load shifting DSM strategy for smart grid applications

    سال انتشار:

    2020


    عنوان انگلیسی مقاله:

    Ensuring the reduction in peak load demands based on load shifting DSM strategy for smart grid applications


    ترجمه فارسی عنوان مقاله:

    تضمین کاهش تقاضای بار اوج بر اساس تغییر استراتژی DSM برای کاربردهای شبکه هوشمند


    منبع:

    Sciencedirect - Elsevier - Procedia Computer Science 167 (2020) 2599–2605


    نویسنده:

    Mande Praveen1,*, G. V. Sivakrishna Rao2


    چکیده انگلیسی:

    In recent year the concept of prosumers (energy producer as well as the consumer) is becoming more popular, and on the other side, demand response has gained attention especially in the smart and micro grid systems. In such power networks, the behaviors of prosumers are highly variable due to many factors and few are price depended, incentive depended etc., Due to the highly dynamic nature of the prosumers, the peak load management is becoming crucial in the power system operation and control especially in smart grids, in which demand side management (DSM) application thought to be useful. This paper presents a simulation study on the role of DSM in the peak load management for a residential community. Here, load shitting-based DSM technique is used. This study considered the daily consumption patterns (hour wise) of electricity using the four types of electric loads. Results showed a considerable decrease in the peak load when compared to the load patterns before applying DSM. The average demand per day in summer is 4.521 kW, and in winter is 3.871 kW. The summary of peak load demands per day in kW without DSM are 14.712 kW, and 18.18 kW for summer and winter respectively. With the load shifting based DSM technique, the peak load per day are reduced to 9.6 kW in the summer season and 9.672 kW in the winter season.
    Keywords: Smart grid | demand side management | load shifting | peak loads | load management | energy management


    سطح: متوسط
    تعداد صفحات فایل pdf انگلیسی: 7
    حجم فایل: 814 کیلوبایت

    قیمت: رایگان