دانلود و نمایش مقالات مرتبط با LEACH::صفحه 1
دانلود بهترین مقالات isi همراه با ترجمه فارسی 2

با سلام خدمت کاربران در صورتی که با خطای سیستم پرداخت بانکی مواجه شدید از طریق کارت به کارت (6037997535328901 بانک ملی ناصر خنجری ) مقاله خود را دریافت کنید (تا مشکل رفع گردد). 

نتیجه جستجو - LEACH

تعداد مقالات یافته شده: 8
ردیف عنوان نوع
1 Urban landfills investigation for leachate assessment using electrical resistivity imaging in Johor, Malaysia
بررسی محل های دفن زباله شهری برای ارزیابی شیرابه با استفاده از تصویربرداری مقاومت الکتریکی در جوهور، مالزی-2021
The use of the electrical resistivity imaging (ERI) approach has expanded dramatically in engineering applications over the years due to the efficiency of the technique in terms of time, expense, and data coverage. The assessment was carried out using ERI to assess the landfill leachate’s pollution level at Simpang Renggam, Johor, Malaysia. The ERI survey was carried out in the research region, utilizing the ABEM Terrameter LS 2 equipment using the Schlumberger electrode configuration. Besides, seven (7) parameters of leachate characterization such as Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD5), Suspended Solid (SS), Power of Hydrogen (pH), Ammonia Hydrogen (NH3-N), Turbidity and Biodegradability Ratio (BOD5/COD) were also performed to identify and evaluate the current leachate condition of the landfill. Furthermore, the study, which involves the measurement of the apparent resistivity of the subsurface materials were able to determine the existence of chemical pollutants in the soil at 1.5 m to 4.0 m depth, with special reference to the chemically apparent resistivity linked with the low resistivity anomalies of 1 – 10 Ωm. Based on the investigations conducted, the physiochemical and microbial analysis of the Simpang Renggam leachate site was found to be 1633 mg/L (Chemical Oxygen Demand), 137.41 mg/L (Biological Oxygen Demand), 359.8 mg/L (Suspended Solid), 7.61 (Power of Hydrogen), 385.29 (Ammonia Hydrogen), 117.65 (Turbidity) and 0.07 (Biodegradability Ratio) which shows that all of the parameter’s value exceeded the value as stated in the local standard which is Environmental Quality Act (1974) except for the pH value which is within the range value as stated in the standard. The leachate from dumps was thought to arise due to system failures in accepting and managing trash, which was exacerbated by the recent high rains. In hindsight, the ERI result was practical for identifying leachate and, therefore, can benefit the authorities in immediate action to halt the extensive water disturbance at the research region.
Keywords: Landfill Leachate | Electrical Resistivity Imaging | Leachate Characterization | Contaminants
مقاله انگلیسی
2 On the volatilisation and decomposition of cyanide contaminations from gold mining
انفجار و تجزیه آلودگی سیانور از استخراج طلا-2018
Cyanide leaching is the predominant process of gold extraction in large scale mining. Current initiatives for reduc ing the use of mercury in small scale and artisanal mining tend towards the cyanide technology as the only fea sible alternative. Thus, the deliberate handling in consideration of the hazardous nature of cyanide compounds is an issue of particular importance. The hydrogen cyanide volatilised during the leaching process and from the tail ings solutions after the gold extraction is reported to be destroyed by oxidation and photolysis from the sur rounding atmosphere of gold mines and the sunlight. Cyanide solutions, drained into the surrounding waterbodies are stated to volatilise at a high rate, thus detoxifying them and releasing hydrogen cyanide to the air. In this study laboratory experiments and field tests were conducted to deliver basic data for the volatilisation and destruction of cyanide in the environment. In our laboratory tests we observed neither oxidation by the oxygen of air nor photolysis by UV-irradiation of cy anides after volatilisation from water. The whole amount of volatilised cyanide was found in the exhaust gas after absorption in a strong basic solution. Field experiments in Segovia (Colombia) could confirm these findings. Cyanide concentrations in a range 17 to 30 mg/L were measured in a local creek. Hydrogen cyanide amounts of 5 ppm were found in the atmosphere sur rounding cyanide leaching facilities. With the findings of this study we want to point out that the concentrations of cyanide in the surrounding of cyanide leaching facilities exceed uncritical limits and a destruction via oxidation and photolysis is not detectable. These conclusions should result in initiatives to protect workers and the sur rounding population of gold mines from contaminations of cyanide treatments.
Keywords: Cyanide ، Oxidation ، Photolysis ، Artisanal gold mining
مقاله انگلیسی
3 Optimal LEACH protocol with modified bat algorithm for big data sensing systems in Internet of Things
پروتکل LEACH بهینه با الگوریتم خفاش اصلاح شده برای سیستم های سنجش از داده های بزرگ در اینترنت اشیا-2018
Big data sensing system (BDSS) plays an important role in the Internet of Things, in which how to reduce power consumption is one crucial problem. Currently, low energy adaptive clustering hierarchy (LEACH) protocol is one well-known algorithm used in BDSS with low energy cost. In this paper, a new variant of bat algorithm combined with centroid strategy is introduced. Three different centroid strategies with six different designs are introduced. In addition, the velocity inertia-free update equation is also provided. The optimization performance is verified by CEC2013 benchmarks in those designs against standard BA. Simulation results prove that the bat algorithm with weighted harmonic centroid (WHCBA) strategy is superior to other algorithms. By integrating WHCBA into LEACH protocol, we develop a two-stage cluster head node selection strategy and can save more energy compared to the standard LEACH protocol.
Keywords: LEACH protocol ، Bat algorithm with centroid strategy ، Inertia-free ، Big data sensing systems
مقاله انگلیسی
4 Coral reef health and management on the verge of a tourism boom: A case study from Miches, Dominican Republic
سلامت و مدیریت صخره مرجانی در آستانه رونق گردشگری: مطالعه موردی از میشیس، جمهوری دومینیکن-2017
The Miches Municipality lies in the second poorest province in the Dominican Republic, and its in habitants rely heavily on nearby coral reefs for food and livelihoods. With the sudden influx of tourism from the completion of a new highway, now is a crucial time to ensure that future tourist development in this region is locally driven and environmentally responsible. As coral reefs are a foundation of Miches identity, economy, and natural wealth, they play an integral role in the realization of this goal. This study employed global reef monitoring protocols to conduct the first-ever quantitative health assessment of Miches reefs in order to guide future management practices. Surveys of multi-taxa indicator species were conducted alongside assessments of coral bleaching, disease prevalence, and evidence of anthro pogenic impacts. Key findings include extremely low abundances of fishery-targeted species, high prevalence of diseased coral, anchor damage at nearly every site, and high abundances of indicator species for nutrient-based pollution such as fertilizers and raw sewage. Deeper, offshore reefs exhibited better health than shallow, inshore reefs, though they were still more degraded than comparable reefs in Dominican marine protected areas. Overall, Miches reefs are highly threatened by four main factors: overfishing, land-based pollution, human-related structural damage, and coral bleaching. To improve the well-being of the regions coral reefs and the communities that depend on them, an adaptive manage ment plan is recommended that encompasses strong fisheries regulations, basic yet consistent moni toring efforts, and the integration of land-based and marine management practices.
Keywords: Coral reefs | Dominican Republic | Tourism | Overfishing | Adaptive management
مقاله انگلیسی
5 Information content of analyst recommendations in the banking industry
محتوای اطلاعاتی از توصیه های تحلیل گران در صنعت بانکی-2017
We investigate whether analyst recommendations about banks become more valuable in periods when the infor mation environment for banks is more uncertain. The degree of uncertainty in the information environment for banks is time-varying because of time-varying changes in information asymmetry for banks and in bank regula tions. Based on a sample of 23,632 analyst recommendations of 1106 banks, we find that analyst recommenda tions are more informative for banks that are riskier and subject to a higher degree of information asymmetry. Furthermore, regulations that reduce the information asymmetry (Sarbanes-Oxley Act) or the risk (Dodd Frank Act) of the banking industry also reduce the information content of analyst recommendations, while regulations that increase the risk of the banking industry (Gramm-Leach-Bliley Act) increase the information content of analyst recommendations. Our results suggest the role of an analyst is more valuable when the infor mation environment is more uncertain.
Keywords: Analyst recommendations | Banking | Information asymmetry | Bank risk | Bank complexity | Bank regulation
مقاله انگلیسی
6 آبشویی وانادیوم با دی اکسید گوگرد از کاتالیزور مصرف شده برای تولید سولفوریک اسید
سال انتشار: 2016 - تعداد صفحات فایل pdf انگلیسی: 7 - تعداد صفحات فایل doc فارسی: 26
در مورد آبشویی تقلیلی وانادیوم از کاتالیزورهای وانادیوم صرف شده برای تولید اسید سولفوریک توسط دی اکسید گوگرد ,با استفاده از محلول های آبی ضعیف اسیدی اسید سولفات , مطالعه های زیادی انجام شده است .میزان تمامیت وانادیوم شسته شده , با حضور آلاینده های فلزات چند ظرفیتی در ارتباط است. اثر پارامترهای مختلف بر روی انحلال وانادیوم درکاتالیزورهایی که دارای محتوای آهن زیادی هستند (1.5٪), تعیین شده است .همچنین داده های به دست امده از نظر مدل های ریاضی برای فرآیندهای ناهمگن , تجزیه و تحلیل شده است .بهترین توصیف فرآیند آبشویی , توسط مدلی ارائه میشود که در ان فرض براین است که تمام محدودیت های این فرایند با انتشار دو واکنش دهنده از طریق لایه نامحلول محصول شکل یافته , صورت میگیرد . این واکنش دهنده ها, هیدروژن و یون وانادیل هستند که به ترتیب دارای نسب واکنش 0.48 و -0.7 می باشند. افزایش دما, اثر قابل توجهی در میزان آبشویی (انرژی فعالسازی 49.24 کیلوژول بر مول ∙-1) دارد . این مقدار از انرژی فعال سازی , می تواند با تغییر در نفوذپذیری محصول نامحلول با افزایش دما ,که در نهایت باعث بهبودمیزان انتشار واکنش دهنده ها میشود , توضیح داده شود .
کلید واژه ها: کاتالیزوره شدن | وانادیوم | آبشویی تقلیلی | دی اکسید گوگرد | پویایی شناسی | کنترل انتشار
مقاله ترجمه شده
7 مطالعه ای بر روی کاهش آلایندگی فنول ها در آب نقاط مختلف نمونه گیری در نزدیکی روخانه پاتالگانگا
سال انتشار: 2016 - تعداد صفحات فایل pdf انگلیسی: 8 - تعداد صفحات فایل doc فارسی: 23
ترکیبات فنولی حضور خود در بدنه های آبی را به عنوان نتیجه ای از فعالیتهای صنعتی نشان داده است که توسط دیگر اغتشاشات طبیعی درحال تولید شدن هستند. بررسی حاضر با مطالعه تاثیرات آبشویی چنین ترکیباتی و نیز کاهش آلایندگی آنها با استفاده از یک سری کربن های به دست آمده از طبیعت که توسط ZnCl2 در آزمایشگاه فعالسازی شده اند سروکار دارد. همه نمونه های آبی برای تعیین محتوای فنولی توسط روش آتی پیرین 4 آمینه تحلیل شده و توسط روش برم دار کردن تایید شدند. این بررسی نتیجه داد که محتوای فنولی در نمونه ها از حداقل ppm 01/0 تا ppm 65/79 متغیر هستند که طبق اعلام سازمان سلامت جهانی بسیار بالاتر از سطح مجاز ppm 2/0 برای تری کلروفنول های 2، 4، 6 و ppm 04/0 برای دی کلروفنول های 2، 4 می باشد. تری کلروفنول های 2، 4، 6 و دی کلروفنول های 2، 4 دو مورد از محتمل ترین ترکیبات فنولی برای اتفاق افتادن در آب آشامیدنی هستند. افزایش مقادیر محتوای فنولی در نمونه های ساولا و جاتادا به تاثیر آبشویی مواد حاصل از صنعت کشت و ساخت و حشره کشی می باشد که در نزدیکی این دهکده ها واقع شده اند. کاهش آلایندگی محتوای فنولی ازطریق آماده سازی کربن های حاصل از مانگیفرا ایندیکا، ساراکا اوسوکا، سیدیم گواجاوا و نیز کربن تجاری انجام شد که در آزمایشگاه با استفاده از ZnCl2 فعالسازی شده اند. هر یک از کربن های طبیعی نشانگر یک ظرفیت متمایز برای کاهش محتوای فنولی بودند.
کلیدواژه ها: روش آنتی پیرین 4 آمینه | روش برم دار کردن | مانگیفرا ایندیکا | ساراکا اوسوکا | سیدیم گواجاوا | کربن تجاری
مقاله ترجمه شده
8 یک خوشه‌بندی فازی بهینه برای شبکه‌های حسگر بیسیم
سال انتشار: 2014 - تعداد صفحات فایل pdf انگلیسی: 16 - تعداد صفحات فایل doc فارسی: 21
حداقل‌سازی مصرف انرژی همیشه در شبکه‌های حسگر یک مسئله مهم بوده است. بیشتر انرژی در انتقال داده از گره حسگر به ایستگاه مرکزی با توجه به طول مسیر از ایستگاه مرکزی مصرف می‌شود. در سال‌های اخیر، تعدادی از پژوهشگران بیان کردند که که خوشه‌بندی یک راه موثر برای کاهش مصرف انرژی در مدت زمان انتقال داده و افزایش طول عمر شبکه‌های حسگر بی‌سیم است. الگوریتم‌های بسیاری تا کنون برای انتخاب راس خوشه پیشنهاد شده‌اند. در این کار، طول عمر شبکه را با سه رویکرد فازی متفاوت انتخاب راس خوشه مقایسه و تحلیل می‌کنیم. سه پارامتر قوی که در ارتقای طول عمر نقش مهمی بازی می‌کنند – انرژی، مرکزیت، و تراکم گره – که برای انتخاب راس خوشه در رویکرد فازی ارائه شده ما بررسی می‌شود. در اولین رویکرد، انرژی و مرکزیت همزمان در سیستم فازی برای انتخاب راس خوشه بررسی شده است. در رویکرد دوم، انرژی و تراکم گره در یک سیستم فازی برای انتخاب راس خوشه در نظر گرفته شده است. در رویکرد سوم، تراکم گره و مرکزیت همزمان توسط یک سیستم فازی برای انتخاب راس گره درنظرگرفته شده است. نتایج شبیه‌سازی این رویکردهای مبتنی بر منطق فازی نشان می‌دهد که سه رویکرد نسبت به خوشه‌بندی سلسله مراتب تطبیقی با انرژی کم (LEACH) برتر هستند. نتایج شبیه سازی همچنین نشان می‌دهد که الگوی خوشه بندی فازی مبتنی بر مرکزیت انرژی بهترین عملکرد را در میان همه سه الگوریتم فازی ارائه می‌دهد و طول عمر شبکه‌های حسگر را به مقدار قابل توجهی ارتقا می‌دهد.
کلمات کلیدی : شبکه حسگر بی‌سیم | خوشه‌بندی | طول عمر | منطق فازی | راس خوشه
مقاله ترجمه شده
rss مقالات ترجمه شده rss مقالات انگلیسی rss کتاب های انگلیسی rss مقالات آموزشی
logo-samandehi
بازدید امروز: 2437 :::::::: بازدید دیروز: 0 :::::::: بازدید کل: 2437 :::::::: افراد آنلاین: 76